Quantum DXi-Datacollector-Sheet
- Introduction
- Compatibility
- Requirements in the CIO Cockpit
- Configuration notes for data collection management
- System access
- KPI scope of the data collection
Introduction
The integration of hardware/software - hereinafter referred to as "system" - into the CIO Cockpit not only requires the registration of the systems themselves but also the configuration of the data collection. Data collection is set up centrally via the Data Collection Management (DCM).
Compatibility
Supported system versions
Quantum DXi is supported by Model 4700 and onwards.
Requirements in the CIO Cockpit
To set up the data collection, the system must first be created in the CIO Cockpit (see FAQs). You can create the system either in the CIO Cockpit Web Frontend or in the Data Collection Management (recommended).
Creation in the CIO Cockpit Web Frontend
Navigation to the system in the CIO Cockpit Web Frontend:
- In the left bar "Configuration" -> "Assets
- In the main window: “Add”, fill in (at least) the mandatory fields and select under "Manufacturer, Asset Type, Product" "Quantum" -> "Backup Device" -> "DXi
Creation in the data collection management
Navigation: "Datacollectors & Assets" -> "Add Datacollector system" -> Selection Vendor: Quantum and Product: DXi
If the system has already been created in the CIO Cockpit Web Frontend, the asset can be selected by clicking on "Use existing element".
Configuration notes for data collection management
Field name | Required content |
---|---|
Hostname | IP or FQDN of the asset |
Port | Port on which the asset is accessible via SSH (default: 22) |
Username | Username for the CIO Cockpit data collection |
Password | Password for the login with the selected user |
Cockpit Reference | The entry for the system in the CIO Cockpit (is set automatically) |
Description | A short description of the created asset (free text field) |
System access
Users and authorizations
To access Quantum DXi via SSH, a user account (recommendation: cockpit_svc) with the authorizations of the default user 'cliviewer' is required.
Network and firewall
The following settings are required for the communication between the data collector and the system:
Source | Destination | Port (default) | Protocol | Direction |
---|---|---|---|---|
datacollector-vm | Quantum DXi | 22 (SSH) | TCP | Outbound |
Deviations from standard settings, e.g. for the port, must be adjusted accordingly.
KPI scope of the data collection
KPI | Details |
---|---|
assetID | The CIO Cockpit ID of the asset. Visible in the asset overview of the CIO Cockpit Web front end |
timestamp | Time stamp with microsecond accuracy of the host OS on which the data collector is running (UTC) |
storageCapacity | Total capacity of the available memory |
storageUsed | Occupied storage space |
storageUncompressed | Capacity of stored data in uncompressed state |
dedupFactor | Compression factor (The dedupFactor is read directly from the Quantum DXi and can be checked as follows: dedupFactor = storageUncompressed / storageUsed) |